Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
Korean Journal of Radiology ; : 355-369, 2022.
Article in English | WPRIM | ID: wpr-926761

ABSTRACT

Objective@#To evaluate the completeness of the reporting of systematic reviews and meta-analyses published in a general radiology journal using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 guidelines. @*Materials and Methods@#Twenty-four articles (systematic review and meta-analysis, n = 18; systematic review only, n = 6) published between August 2009 and September 2021 in the Korean Journal of Radiology were analyzed. Completeness of the reporting of main texts and abstracts were evaluated using the PRISMA 2020 statement. For each item in the statement, the proportion of studies that met the guidelines’ recommendation was calculated and items that were satisfied by fewer than 80% of the studies were identified. The review process was conducted by two independent reviewers. @*Results@#Of the 42 items (including sub-items) in the PRISMA 2020 statement for main text, 24 were satisfied by fewer than 80% of the included articles. The 24 items were grouped into eight domains: 1) assessment of the eligibility of potential articles, 2) assessment of the risk of bias, 3) synthesis of results, 4) additional analysis of study heterogeneity, 5) assessment of non-reporting bias, 6) assessment of the certainty of evidence, 7) provision of limitations of the study, and 8) additional information, such as protocol registration. Of the 12 items in the abstract checklists, eight were incorporated in fewer than 80% of the included publications. @*Conclusion@#Several items included in the PRISMA 2020 checklist were overlooked in systematic review and meta-analysis articles published in the Korean Journal of Radiology. Based on these results, we suggest a double-check list for improving the quality of systematic reviews and meta-analyses. Authors and reviewers should familiarize themselves with the PRISMA 2020 statement and check whether the recommended items are fully satisfied prior to publication.

2.
Korean Journal of Radiology ; : 684-694, 2020.
Article | WPRIM | ID: wpr-833559

ABSTRACT

Objective@#The purpose was to review the diagnostic performance of the length of tumor capsular contact (LCC) on magnetic resonance imaging (MRI) for detecting prostate cancer extraprostatic extension (EPE). @*Materials and Methods@#PubMed and EMBASE databases were searched up to March 24, 2019. We included diagnostic accuracy studies that evaluated LCC on MRI for EPE detection using radical prostatectomy specimen histopathology as the reference standard. Quality of studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Sensitivity and specificity were pooled and graphically presented using hierarchical summary receiver operating characteristic (HSROC) plots. Meta-regression and subgroup analyses were conducted to explore heterogeneity. @*Results@#Thirteen articles with 2136 patients were included. Study quality was generally good. Summary sensitivity and specificity were 0.79 (95% confidence interval [CI] 0.73–0.83) and 0.67 (95% CI 0.60–0.74), respectively. Area under the HSROC was 0.81 (95% CI 0.77–0.84). Substantial heterogeneity was present among the included studies according to Cochran’s Q-test (p < 0.01) and Higgins I2 (62% and 86% for sensitivity and specificity, respectively). In terms of heterogeneity, measurement method (curvilinear vs. linear), prevalence of Gleason score ≥ 7, MRI readers’ experience, and endorectal coils were significant factors (p ≤ 0.01), whereas method to determine the LCC threshold, cutoff value, magnet strength, and publication year were not (p = 0.14–0.93). Diagnostic test accuracy estimates were comparable across all assessed MRI sequences. @*Conclusion@#Greater LCC on MRI is associated with a higher probability of prostate cancer EPE. Due to heterogeneity among the studies, further investigation is needed to establish the optimal cutoff value for each clinical setting.

3.
Korean Journal of Radiology ; : 378-384, 2019.
Article in English | WPRIM | ID: wpr-741427

ABSTRACT

OBJECTIVE: To directly compare the diagnostic performance of true and oblique axial T2-weighted imaging (T2WI) for assessing parametrial invasion (PMI) in cervical cancer. MATERIALS AND METHODS: This retrospective study included 71 women with treatment-naive cervical cancer who underwent MRI that included both oblique and true axial T2WI, followed by radical hysterectomy. Two blinded radiologists (Radiologist 1 and Radiologist 2) independently assessed the presence of PMI on both sequences using a 5-point Likert scale. Receiver operating characteristic (ROC) curve analysis was performed, with a subgroup analysis for tumors sized > 2.5 cm and ≤ 2.5 cm in diameter. Inter-reader agreement was assessed with kappa (k) statistics. RESULTS: At hysterectomy, 15 patients (21.1%) had PMI. For Radiologist 1, the area under the ROC curve (AUC) was greater for oblique axial than for true axial T2WI {0.941 (95% confidence interval [CI] = 0.858–0.983) vs. 0.917 (95% CI = 0.827–0.969), p = 0.027}. The difference was not significant for Radiologist 2 (0.879 [95% CI = 0.779–0.944] vs. 0.827 [95% CI = 0.719–0.906], p = 0.153). For tumors > 2.5 cm, AUC was greater with oblique than with true axial T2WI (0.906 vs. 0.860, p = 0.046 for Radiologist 1 and 0.839 vs. 0.765, p = 0.086 for Radiologist 2). Agreement between the radiologists was almost perfect for oblique axial T2WI (k = 0.810) and was substantial for true axial T2WI (k = 0.704). CONCLUSION: Oblique axial T2WI potentially provides greater diagnostic performance than true axial T2WI for determining PMI, particularly for tumors > 2.5 cm. The inter-reader agreement was greater with oblique axial T2WI.


Subject(s)
Female , Humans , Area Under Curve , Hysterectomy , Magnetic Resonance Imaging , Retrospective Studies , ROC Curve , Uterine Cervical Neoplasms
4.
Korean Journal of Radiology ; : 1119-1129, 2018.
Article in English | WPRIM | ID: wpr-718937

ABSTRACT

OBJECTIVE: To compare the image quality of low-tube-voltage and low-iodine-concentration-contrast-medium (LVLC) computed tomography urography (CTU) with iterative reconstruction (IR) with that of conventional CTU. MATERIALS AND METHODS: This prospective, multi-institutional, randomized controlled trial was performed at 16 hospitals using CT scanners from various vendors. Patients were randomly assigned to the following groups: 1) the LVLC-CTU (80 kVp and 240 mgI/mL) with IR group and 2) the conventional CTU (120 kVp and 350 mgI/mL) with filtered-back projection group. The overall diagnostic acceptability, sharpness, and noise were assessed. Additionally, the mean attenuation, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and figure of merit (FOM) in the urinary tract were evaluated. RESULTS: The study included 299 patients (LVLC-CTU group: 150 patients; conventional CTU group: 149 patients). The LVLC-CTU group had a significantly lower effective radiation dose (5.73 ± 4.04 vs. 8.43 ± 4.38 mSv) compared to the conventional CTU group. LVLC-CTU showed at least standard diagnostic acceptability (score ≥ 3), but it was non-inferior when compared to conventional CTU. The mean attenuation value, mean SNR, CNR, and FOM in all pre-defined segments of the urinary tract were significantly higher in the LVLC-CTU group than in the conventional CTU group. CONCLUSION: The diagnostic acceptability and quantitative image quality of LVLC-CTU with IR are not inferior to those of conventional CTU. Additionally, LVLC-CTU with IR is beneficial because both radiation exposure and total iodine load are reduced.


Subject(s)
Humans , Commerce , Contrast Media , Iodine , Noise , Prospective Studies , Radiation Exposure , Signal-To-Noise Ratio , Urinary Tract , Urography
5.
Journal of Gynecologic Oncology ; : e98-2018.
Article in English | WPRIM | ID: wpr-718162

ABSTRACT

OBJECTIVE: We describe a systematic review and meta-analysis of the performance of 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) for detecting metastasis in ovarian cancer. METHODS: MEDLINE and Embase were searched for diagnostic accuracy studies that used 18F-FDG PET or PET/CT for pre-treatment staging, using surgical findings as the reference standard. Sensitivities and specificities were pooled and plotted in a hierarchic summary receiver operating characteristic plot. Potential causes of heterogeneity were explored through sensitivity analyses. RESULTS: Eight studies with 594 patients were included. The overall pooled sensitivity and specificity for metastasis were 0.72 (95% confidence interval [CI]=0.61–0.81) and 0.93 (95% CI=0.85–0.97), respectively. There was considerable heterogeneity in sensitivity (I2=97.57%) and specificity (I2=96.74%). In sensitivity analyses, studies that used laparotomy as the reference standard showed significantly higher sensitivity and specificity (0.77; 95% CI=0.67–0.87 and 0.96; 95% CI=0.92–0.99, respectively) than those including diagnostic laparoscopy (0.62; 95% CI=0.46–0.77 and 0.84; 95% CI=0.69–0.99, respectively). Higher specificity was shown in studies that confirmed surgical findings by pathologic evaluation (0.95; 95% CI=0.90–0.99) than in a study without pathologic confirmation (0.69; 95% CI=0.24–1.00). Studies with a lower prevalence of the FDG-avid subtype showed higher specificity (0.97; 95% CI=0.94–1.00) than those with a greater prevalence (0.89; 95% CI=0.80–0.97). CONCLUSION: Pre-treatment 18F-FDG PET/CT shows moderate sensitivity and high specificity for detecting metastasis in ovarian cancer. With its low false-positive rate, it can help select surgical approaches or alternative treatment options.


Subject(s)
Humans , Electrons , Fluorodeoxyglucose F18 , Laparoscopy , Laparotomy , Neoplasm Metastasis , Ovarian Neoplasms , Population Characteristics , Positron-Emission Tomography , Positron Emission Tomography Computed Tomography , Prevalence , ROC Curve , Sensitivity and Specificity
6.
Korean Journal of Radiology ; : 99-113, 2015.
Article in English | WPRIM | ID: wpr-157424

ABSTRACT

The prevalence of small renal masses (SRM) has risen, paralleling the increased usage of cross-sectional imaging. A large proportion of these SRMs are not malignant, and do not require invasive treatment such as nephrectomy. Therefore, differentation between early renal cell carcinoma (RCC) and benign SRM is critical to achieve proper management. This article reviews the radiological features of benign SRMs, with focus on two of the most common benign entities, angiomyolipoma and oncocytoma, in terms of their common imaging findings and differential features from RCC. Furthermore, the role of percutaneous biopsy is discussed as imaging is yet imperfect, therefore necessitating biopsy in certain circumstances to confirm the benignity of SRMs.


Subject(s)
Humans , Abdominal Fat/pathology , Adenoma, Oxyphilic/diagnosis , Angiomyolipoma/diagnosis , Carcinoma, Renal Cell/diagnosis , Diagnosis, Differential , Kidney Neoplasms/diagnosis , Leiomyoma/diagnosis
7.
Korean Journal of Radiology ; : 1029-1037, 2015.
Article in English | WPRIM | ID: wpr-163300

ABSTRACT

OBJECTIVE: To evaluate the utility of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) using macromolecular contrast agent (P792) for assessment of vascular disrupting drug effect in rabbit VX2 liver tumor models. MATERIALS AND METHODS: This study was approved by our Institutional Animal Care and Use Committee. DCE-MRI was performed with 3-T scanner in 13 VX2 liver tumor-bearing rabbits, before, 4 hours after, and 24 hours after administration of vascular disrupting agent (VDA), using gadomelitol (P792, n = 7) or low molecular weight contrast agent (gadoterate meglumine [Gd-DOTA], n = 6). P792 was injected at a of dose 0.05 mmol/kg, while that of Gd-DOTA was 0.2 mmol/kg. DCE-MRI parameters including volume transfer coefficient (K(trans)) and initial area under the gadolinium concentration-time curve until 60 seconds (iAUC) of tumors were compared between the 2 groups at each time point. DCE-MRI parameters were correlated with tumor histopathology. Reproducibility in measurement of DCE-MRI parameters and image quality of source MR were compared between groups. RESULTS: P792 group showed a more prominent decrease in K(trans) and iAUC at 4 hours and 24 hours, as compared to the Gd-DOTA group. Changes in DCE-MRI parameters showed a weak correlation with histologic parameters (necrotic fraction and microvessel density) in both groups. Reproducibility of DCE-MRI parameters and overall image quality was not significantly better in the P792 group, as compared to the Gd-DOTA group. CONCLUSION: Dynamic contrast-enhanced magnetic resonance imaging using a macromolecular contrast agent shows changes of hepatic perfusion more clearly after administration of the VDA. Gadolinium was required at smaller doses than a low molecular contrast agent.


Subject(s)
Animals , Male , Rabbits , Antineoplastic Agents/therapeutic use , Benzophenones/therapeutic use , Disease Models, Animal , Heterocyclic Compounds/administration & dosage , Liver Neoplasms/drug therapy , Magnetic Resonance Imaging , Organometallic Compounds/administration & dosage , Reproducibility of Results , Valine/analogs & derivatives
8.
Korean Journal of Radiology ; : 1373-1373, 2015.
Article in English | WPRIM | ID: wpr-172966

ABSTRACT

The publisher and authors would like to draw the reader's attention to an error.

9.
Ultrasonography ; : 191-199, 2014.
Article in English | WPRIM | ID: wpr-731135

ABSTRACT

PURPOSE: The aim of this study was to evaluate the safety and accuracy of a new portable ultrasonography-guided high-intensity focused ultrasound (USg-HIFU) system with a 3-dimensional (3D) electronic steering transducer, a simultaneous ablation and imaging module, real-time cavitation monitoring, and 3D image reconstruction algorithms. METHODS: To address the accuracy of the transducer, hydrophones in a water chamber were used to assess the generation of sonic fields. An animal study was also performed in five pigs by ablating in vivo thighs by single-point sonication (n=10) or volume sonication (n=10) and ex vivo kidneys by single-point sonication (n=10). Histological and statistical analyses were performed. RESULTS: In the hydrophone study, peak voltages were detected within 1.0 mm from the targets on the y- and z-axes and within 2.0-mm intervals along the x-axis (z-axis, direction of ultrasound propagation; y- and x-axes, perpendicular to the direction of ultrasound propagation). Twenty-nine of 30 HIFU sessions successfully created ablations at the target. The in vivo porcine thigh study showed only a small discrepancy (width, 0.5-1.1 mm; length, 3.0 mm) between the planning ultrasonograms and the pathological specimens. Inordinate thermal damage was not observed in the adjacent tissues or sonic pathways in the in vivo thigh and ex vivo kidney studies. CONCLUSION: Our study suggests that this new USg-HIFU system may be a safe and accurate technique for ablating soft tissues and encapsulated organs.


Subject(s)
Animals , Ablation Techniques , Animal Experimentation , Equipment and Supplies , High-Intensity Focused Ultrasound Ablation , Image Processing, Computer-Assisted , Kidney , Sonication , Swine , Thigh , Transducers , Ultrasonography , Water
10.
Ultrasonography ; : 136-142, 2014.
Article in English | WPRIM | ID: wpr-731022

ABSTRACT

PURPOSE: The aim of this study was to explore the usefulness of the resistive index (RI) on spectral Doppler ultrasonography (US) in the detection of renal cell carcinoma (RCC) in patients with end-stage renal disease (ESRD). METHODS: Seventeen ESRD patients with kidneys in which renal masses were suspected in routine US were subjected. They underwent computed tomography scans and additional Doppler US for the characterization of the detected lesions. All underwent radical nephrectomy with the suspicion of RCC. Fourteen patients finally were included. RI measurements were conducted in the region of the suspected renal mass and the background renal parenchyma. The intraclass correlation coefficient was used to assess the reproducibility of the RI measurement. A paired t-test was used to compare the RI values between the renal mass and the background renal parenchyma (P<0.05). RESULTS: The RI values measured at the RCCs were significantly lower than those measured at the background renal parenchyma (0.41-0.65 vs. 0.75-0.89; P<0.001). The intrareader reproducibility proved to be excellent and good for the renal masses and the parenchyma, respectively (P<0.001). CONCLUSION: RI on spectral Doppler US is useful in detecting RCC in patients with ESRD. The RI values measured at the RCCs were significantly lower than those measured at the background renal parenchyma.


Subject(s)
Humans , Carcinoma, Renal Cell , Kidney , Kidney Failure, Chronic , Nephrectomy , Ultrasonography, Doppler , Ultrasonography, Doppler, Color , Ultrasonography, Doppler, Pulsed
11.
Korean Journal of Radiology ; : 254-257, 2014.
Article in English | WPRIM | ID: wpr-187064

ABSTRACT

A rubber tip disconnection of Arrow-Trerotola percutaneous thrombolytic device (PTD) may occur occasionally. We experienced 5 cases of a rubber tip disconnection among 453 mechanical thrombectomy sessions with the use of PTD. We present a report about these five cases and suggest possible causes for the occurrences.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Catheter Obstruction/etiology , Equipment Failure Analysis/methods , Renal Dialysis/instrumentation , Rubber , Thrombectomy/instrumentation , Treatment Outcome
12.
Korean Journal of Radiology ; : 346-355, 2014.
Article in English | WPRIM | ID: wpr-203185

ABSTRACT

OBJECTIVE: To assess the diagnostic value of shear wave elastography (SWE) for prostate cancer detection. MATERIALS AND METHODS: In this retrospective study, 87 patients with the suspicion of prostate cancer (prostate-specific antigen > 4 ng/mL and abnormal digital rectal examination) underwent a protocol-based systematic 12-core biopsy followed by targeted biopsy at hypoechoic areas on grey-scale ultrasound. Prior to biopsy, SWE was performed by placing two circular 5 mm-sized regions of interest (ROIs) along the estimated biopsy tract in each sector and one ROI for hypoechoic lesions. SWE parameters, S (mean stiffness) and R (mean stiffness ratio), were calculated and compared regarding different histopathologic tissues and their accuracy for diagnosing prostate cancer was analyzed. SWE parameters were correlated with Gleason score and were compared between indolent ( or = 8) tissues in prostate cancer patients. RESULTS: Prostate cancer was detected in 7.5% of 1058 cores in 29.9% of 87 patients. Seven (43.8%) of 16 hypoechoic lesions were confirmed as prostate cancer. SWE parameters were significantly different among the histopathologic entities (p 43.9 kPa and 60.8%, 66.4%, and 0.653, respectively, for R > 3. Both, S and R showed a significant correlation with Gleason score (r > or = 0.296, p < or = 0.008) and were significantly different between indolent and aggressive prostate cancer (p < or = 0.006). CONCLUSION: Shear wave elastographic parameters are significantly different between prostate cancer and benign prostate tissue and correlate with Gleason score.


Subject(s)
Adult , Aged , Aged, 80 and over , Humans , Male , Middle Aged , Biopsy , Elasticity Imaging Techniques/methods , Neoplasm Grading , Prostate/pathology , Prostate-Specific Antigen/blood , Prostatic Neoplasms/pathology , ROC Curve , Retrospective Studies , Sensitivity and Specificity , Ultrasonography, Interventional/methods
SELECTION OF CITATIONS
SEARCH DETAIL